    Description

    First Automation
    1PCS UA6013L Capacitor Digital Auto Range LCD Monitor Capacitance Tester Meter
    6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD. Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,000μF. It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
    Features
    1. It is applied with CMOS double-bevel A/D convertor that is automatic in zeroing and polar selection, and makes instruction for beyond measuring range.
    2. Wide measuring range, covering 9 measuring sections from 0.1pF to 20,000μF that includes nominal value of any capacitance.
    3. Biggest display value: 1999(3 1/2).
    4. Reading: 2-3 readings/sec.
    5.Zeroing: There is a zeroing knob on the front, easy for operation.
    6. Data hold: Put the “HOLD” switch to "ON" and the DH sign will appear on the display.
    7. Press “” button , the back light will light.
    8. Temperature for accurate measuring: 25℃±5℃
    9. Temperature range: working temperature: 0℃ to 40℃
    Storage temperature: -10℃ to 50℃
    10. Relative humidity: <80%
    11. Power: a 9V laminated battery
    12. Instruction for low voltage of battery: showing“” signal on the left-upper of the LCD.
    Technical specifications
    Accuracy: ±(%reading±digits) Quality guarantee: one year
    Environment temperature: 25℃±5℃
    Relative humidity: <80%
    Rang
    Accuracy
    Definition
    Testing frequency
    200pF
    ±
    0.5%±20digit
    0.1pF
    800Hz
    2nF
    ±
    0.5%±20digit
    1pF
    800Hz
    20nF
    ±
    0.5%±20digit
    10pF
    800Hz
    200nF
    ±
    0.5%±20digit
    0.1
    μF
    800Hz
    2
    μF
    ±
    0.5%±20digit
    1nF
    800Hz
    20
    μF
    ±
    0.5%±20digit
    10nF
    80Hz
    200
    μF
    ±
    0.5%±20digit
    0.1
    μF
    8Hz
    2000
    μF
    ±
    2.0%±20digit
    1
    μF
    8Hz
    20000
    μF
    ±
    4.0%±20digit
    10
    μF
    8Hz
    Operation
    Firstly, check a 9V battery whether its electric voltage is short that will show “” signal on the left-upper of the LCD. Secondly, pay attention to the polarity or the capacitance to be tested. Thirdly, recharge the capacitance before measuring.
    1. Select proper measuring section according to the capacitance to be tested.
    2. Check and use the zeroing knob on the front of the meter to adjust the value to zero before measuring.
    3. Insert the black sensor into the jack with “-”signal and the red sensor into the jack with “+”.
    4. Connect the capacitance to be tested with the two sensors. Pay attention to the polarity of the capacitance ! Read capacitance numerical value displayed.
    Notes
    a. If you don’t know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
    b. If the capacitance is in short circuit, the meter shows “beyond measuring range ”. If the capacitance is in electric leakage, the meter shows “beyond measuring range ”or “much bigger than the normal value ”. If the capacitance is open-circuit, the meter shows “Zero ”or “several pF ”.
    c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
    Maintenance
    The meter is of highly accurate electronic apparatus. Don’t change its internal circuit rashly for no damage to the meter.
    1. Don’t exert electric voltage upon the jack parts of the meter for no damage to the meter.
    2. Don’t test the sensors in short circuit , or the battery will be consumed out quickly.
    3. Don’t use a meter whose back cover doesn’t cover the meter well.
    4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is φ5×20㎜.
    5. Please take out the battery when not using for a long time.
    Power Supply: 9V battery
    (not included)
    Size: As the picture shows
    Quantity:1 PC
    Notice: According to international shipping requirements, it is forbidden to have powder, liquid, nor battery in package,In order to avoid delay of transportation, we will have to check and take out these items before packing.
    Payment:
    We currently only accept payment through PayPal.
    Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.
    Feedback:
    We strive for positive Feedback on all transactions and nothing less than an overall Detail Seller Rating (DSR) of 5 STAR.If you are considering giving a neutral or negative Feedback or a low DSR. Do write to us and give us an opportunity to address your concerns firstly.We will leave the positive feedback when we got your positive feedback.
    Delivery details:
    We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address.
    Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.)
    RETURN POLICY:
    We offer 14 days return policy from the day you received your item under the following conditions All returns must be in the original non-damaged condition, including packaging, documentation, warranty cards, manuals and accessories or else it will not be accepted.
    Original shipping & handling charges are not refundable.
    Customer is responsible for shipping, shipping cost and proof of delivery on all returns. Please be sure that you return shipments are properly packed and fully insured. We are not responsible for returned packages if lost by shipper/carrier or got damaged buy carrier.
    Shipping cost (to and from buyer) will be charged for any refused shipping delivery (include duties, taxes and customs fee if any).
    TAX&VAT
    Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it.
    Contact us:
    Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.
    Copyright 2018 First Automation. All rights reserved.